Beijing Medcare Biotech Co., Ltd
|
|
| |
Test Reader: Photometer, Elisa Micro Plate Reader and Elisa Washer
|
Click to enlarge image
|
|

|
1. hermetic solid-state optical system, stable performance with low contamination of dust and dampness, longer life time of hard membrane filters than soft ones.
2. Light split after the cuvette, corresponding every wavelength, there are independent amplifier . Switch between different wave length completed by electric multiplexer, no mechanical movement, useful for bichromatic measurement.
3. Dedicated touch-input keyboard, optional Menu and instruction step by step. It can checking the status of the unit.
4. 240X128 dot matrix LCD with back-lit, can display ASC code and curve simultaneously, readable even if in the dim light.
5. Show the real time.
6. 58mm thermal printer, high speed and lower noise, optional external printer.
7. Measure methods: End point method, Fixed time method, Kinetic method and coagulation time method.
8. Light source: halogen lamp12V/ 20W.
9. Optical system: 340, 405, 505, 546, 578, 630nm, precision: +/-3nm.
10. Absorbance range:0.0000 2.5000ABS
11. After 10 minutes warm up, the drift<0.003Abs/hr
12. cuvette:10mm, 33ul, when the aspiration volume ≥500ul, the carry over <1.0%
13. temperature control: 25, 30, 32, 37+/-0.1Centigrade.
14. precision: when Abs.=0.5000,CV<0.1%; when Abs.=2.0000,CV<1%.
15. 96 different analysis can be set in.
16. power supply: 110/220V±10%, 50/60Hz, <80VA
17.RS232: standard serial port.
wohbc-100 PHTOMETER can print summary report list, keep at most 1000 tests, 100 samples and each sample has 256 tests.
wohbc-100 PHTOMETER has big EEPROM. The user can set up 96 tests in 6 different sub-divisions as: assay1, assay2, assay3, assay4, assay5, assay6. Each test has at most 6 different standard calibrator.
The kinetic measuring time of wohbc-100 PHTOMETER can last for 66 minutes, which is very useful for research and pharmacy analysis.
1 Elisa washer Work Conditions
(1) Environmental temperature: 5-40C;
(2) Relative humidity: <=80%;
(3) Be away form dust, shake and caustic gas;
(4) The single-phase AC power supply should be grounded perfectly.
AC220X(1+/-10%)V, 50/60 Hz, 30VA;
(5) Fuse: 5x20 2A;
(6) Safety type: Class: I; Group: B.
1.2 Storage and Transportation Conditions
(1) Environmental temperature: -20C to +55C
(2) Relative humidity: <=93%;
(3) No caustic gases;
(4) Good ventilation.
WOHBC Elisa reader: Range of working wavelength is from 400nm to 700nm. It has 4 filters when leaving factory: 405nm, 450nm, 492nm, 630nm;
(1) Characteristics of the filters
(3) Detection range of the instrument is from 0.1A to 3.0A. The error of absorbance accuracy is as follows:
(5) Repeatability: <1.0%;
(6) Stability: <+/-0.005A/10min;
(7) Detection modes: single wavelength or dual wavelengths;
(8) Display: 240x128 pixels LCD screen;
(9) Print: external printer;
(10) Data Link: RS232 serial port;
(11) Output: absorbance, qualitative judgment, value of P/CO, concentration, judgment of normal value and quality control value
(12) Dimensions: 420x290x180mm:
(13) Weight: 10Kg.
3.1 Work Conditions
(1) Environmental temperature: 10-30C;
(2) Relative humidity: <=70%;
(2) Be away from strong electromagnetic field;
(3) Avoid direct irradiation from strong light;
(4) The work place must be dustproof and shake-proof. There should be no caustic gas such as hydrochloric acid in the air;
(5) Power supply: 220X(1+/-10%)V, 50X(1+/-2%)Hz;
(6) Power supply must be grounded perfectly.
|
|
| |
|
|
|